Ionic Contamination Measurement System ROSE Tester 54

SKU: ROSE Tester 54 Category: Tags: , , ,
  • Brand:捷克DCT
  • The devices are intended for precise measurement of ionic contamination (contamination of ionic impurities) in the Electrotechnical industry, especially for controlling purity of PCBs and misprints. Due to their precision, Rose Testers can be used for measuring purity in other industries as well.
  • Ionic impurities are invisible with bare eye check or under a microscope. This is the reason why the usage of Rose Tester is necessary for revealing such kind of impurities. The result of testing is a value μg NaCI Eq./cm2
  • This particular check of ionic contamination level is usually performed after the cleaning process of PCB, as a quality and sustainability check. The aim of this measurement is to ensure the reliability of the product, which could be harmed by undesirable ionic contamination.
  • Measurement systems Rose Tester 32 and Rose Tester 54 are developed and manufactured in accordance with a standard IPC-TM-650, 2.3.25 (Static Extraction Method)

Specification

ModelROSE Tester 54
Dimension822×778×744 mm
Weight130 kg
Dimension with handling trolley822×778×1110 mm
Weight with handling trolley140 kg
Ø energy consumption per cycle0,5 kWh
Minimal size of PCB300 cm2(Total PCB area on Both Sides)
Maximal size of PCB130×485×400 mm
Maximum number of signs of tested PCB80 signs
Extraction solution IPA / DI Water75 : 25
Volume of tested chamber40 升
Adjustable temperature of tested mediumroom temperature up to 40°C
Automatic deionization of tested fl uidActive carbon and ionex fi lters (replaceable)
Sensitivity of the conductivity sensor0,0001 μS/cm
Accuracy of conductivity sensor±0,5 %
Calibration conductivity sensor (WTW) at 5 μS/cmThe tolerance at ± 0,04 μS/cm
Measurement Resultμg NaCI Eq./cm2
Measurement Range0–99 μg NaCl/cm2
Measuring StandardIPC-TM-650, 2.3.25
Noize Level<54 dB
Device ControlPLC + 8,4” touchscreen
Power Supply230V, 50Hz